New mains, supplied and laid
Scotland-wide supply, lay, construction and testing of new water, fire, sprinkler and rising mains as a WIRS accredited contractor.

Service
Data-logged hydrostatic pressure testing that proves a new main holds working pressure before it is tied in and buried. We test PE, MDPE, barrier and ductile.
A leak found after connection means digging up a live tie-in, a stalled programme and a very different repair bill. A pressure test finds it while the fault is still cheap to reach. We fill the main, bring it up to working pressure and hold it, then monitor the loss against the allowable figure for the pipe material and length.
The test is data-logged, so you get a clear record of what the main did under pressure, not just a verbal pass. We test PE, MDPE, barrier and ductile mains. Where we have swabbed and cleared the pipe first, the test is clean and the result stands, which is why we never test a main that has not been properly swabbed.

A foam swab is driven through the length of the main to push out trapped air and the debris left behind during installation.
Stage focus:
The main is filled, brought up to working pressure and held, then monitored against the allowable loss for the pipe and length. We test PE, MDPE, barrier and ductile.
Stage focus:
A dosed disinfection solution is introduced and held in the main for the required contact time, then dechlorinated and flushed down to the network residual.
Stage focus:
Water samples are drawn from the disinfected main and sent for laboratory analysis against the potable standard.
Stage focus:
The results from every stage are assembled into the auditable certificate pack that Scottish Water accepts to permit connection.
Stage focus:
We test PE, MDPE, barrier and ductile mains, both adoptable and private. We monitor the pressure loss against the allowable figure for that pipe material and the length of the run, so the pass reflects the main you actually have.
Yes. The test is data-logged, so you get a clear record of the pressure held and the loss measured over the test period. That record goes into the certificate pack the water authority and Building Control expect, rather than a verbal pass.
Always. Air and debris left in the pipe can invalidate a pressure test and cause a sample to fail later. We swab and flush the main clear first, so the test is clean and the result stands. We never test a main that has not been properly swabbed.
We find the fault while the pipe is still accessible, before it is tied in and buried, which is the whole point of testing first. That keeps the repair cheap and the programme intact, rather than digging up a live connection later.